G protein-coupled receptor
Nociceptin/ORL1 receptor
Nociceptin opioid peptide receptor
- GeneOPRL1
- FamilyOpioid receptors
- GroupOpioid receptors
The NOP receptor was cloned from human brainstem under the name ORL1, for opioid receptor-like. It is a G protein-coupled receptor whose sequence is about half identical to the μ, δ and κ receptors, yet it does not behave like a typical opioid receptor.1
Its natural agonist is a peptide of 17 amino acids that two groups found independently and named nociceptin and orphanin FQ. Given into the brain of mice, it did not relieve pain like the opioids. Both groups instead saw increased sensitivity to pain, and one also saw reduced movement.2,3
Sources (3)
- Mollereau et al. 1994Mollereau C, Parmentier M, Mailleux P, et al. (1994) ORL1, a novel member of the opioid receptor family. Cloning, functional expression and localization FEBS Lett
- Meunier et al. 1995Meunier JC, Mollereau C, Toll L, et al. (1995) Isolation and structure of the endogenous agonist of opioid receptor-like ORL1 receptor Nature
- Reinscheid et al. 1995Reinscheid RK, Nothacker HP, Bourson A, et al. (1995) Orphanin FQ: a neuropeptide that activates an opioidlike G protein-coupled receptor Science
Binding affinity (Kᵢ)
1 substance, 1 displayed value. Strongest first within each organism. The bar is pKᵢ on a log scale. Open a row to see the assay and every report behind the value.
Human
1 measurement
Buprenorphine285 nMHuang et al. 2001
- Assay
- recombinant human NOP/ORL1 in CHO membranes, [3H]nociceptin/OFQ competition
- Shown value from
- Huang et al. 2001, Table 1
- Error
- ± 30 SEM, n = 3
Functional potency (EC₅₀)
1 substance, 1 displayed value. Strongest first within each organism. Emax is shown where the paper reports it. Efficacy depends on the assay and its reference agonist.
Human
1 measurement
Buprenorphine35 nMHuang et al. 2001
- Assay
- recombinant human NOP/ORL1 in CHO membranes, [35S]GTPgammaS functional assay
- Shown value from
- Huang et al. 2001, Table 2
- Error
- ± 8.0 SEM
- Emax
- 60.0 ± 10.0%
Values are published numbers in nM per organism. Different assays, species and receptor preparations are not directly interchangeable, and a value does not establish clinical potency or safety.